Diagnostic Performance of Contrast-Enhanced Ultrasound in Testicular Space-Occupying Lesions: A Systematic Review and Meta-analysis

Acad Radiol. 2024 May 6:S1076-6332(24)00239-3. doi: 10.1016/j.acra.2024.04.030. Online ahead of print.

Abstract

Purpose: Contrast-enhanced ultrasound (CEUS) has been increasingly used for the diagnostic identification of neoplasms due to its ability to visualize the microvascularization of lesions. In the study of testicular abnormalities, the appropriate use of CEUS can improve the diagnostic accuracy of conventional gray-scale ultrasound and color Doppler ultrasound (CDUS). The purpose of this study is to comprehensively evaluate the diagnostic performance of CEUS in testicular space-occupying lesions.

Methods: A comprehensive search of PubMed, Embase, Cochrane Library, and Web of Science databases was conducted from the inception of each database to November 16, 2022 for relevant studies. The required data were extracted, and the methodological quality of the studies was assessed using the QUADAS-2 tool. The diagnostic value of CEUS was assessed by calculating the combined sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio, and a summary receiver operating characteristic (SROC) curve was used to conduct this meta-analysis.

Results: A total of six studies with 354 testicular space-occupying lesions were included in the analysis. The results showed that CEUS could provide additional useful information for the diagnosis of testicular space-occupying lesions, with a sensitivity of 0.92 (95% CI:0.82, 0.97), specificity of 0.91 (95% CI:0.80, 0.96), diagnostic odds ratio of 114 (95% CI:25, 528), respectively, and an overall diagnostic accuracy expressed as area under the SROC curve (AUC) of 0.97 (95% CI:0.95-0.98). Significant heterogeneity was seen in the sensitivity with I2 = 82.53% (95% CI:69.44-95.61). Subgroup analysis revealed that the proportion of infertile patients selected may be the source of heterogeneity.

Conclusion: CEUS can be used to diagnose testicular space-occupying lesions more accurately and improve diagnostic accuracy when the conventional US cannot accurately differentiate the type of lesion. In particular, CEUS should be recommended for the identification of microscopic lesions so that physicians can provide patients with more appropriate interventions to avoid unnecessary orchiectomy.

Keywords: Contrast-enhanced ultrasound; Diagnostic; Meta-analysis; Testicular space-occupying lesions.

Publication types

  • Review